Product
Automated Library Preparation System
AxiLona Auto Lib Prep

A fully automated, standardized, high-throughput, and efficient automated system designed and developed for library preparation. It does not require manual operation and can process up to 8 samples in each batch, which greatly shortens the library construction time.


*For research use only (RUO)

×
Advantage
Fully Automated Workflow

Eliminates manual operations, significantly reducing labor costs and human error


01
/
04
Standardized and Precise Process

Ensures consistent pipetting accuracy, minimizing variability and errors in library preparation


02
/
04
High Throughput and Efficiency

Enables batch processing of up to 8 samples simultaneously, dramatically shortening library preparation time


03
/
04
Cost-Effective Solution

Reduces reagent waste and operational expenses while maintaining consistent, high-quality process




04
/
04
Panel Menu
功能模块
Single channel pipetting module Adopts capacitance/pressure dual induction, with liquid level detection,
Clot detection, vacuum detection and tip detection functions
Pipetting range: 1-1,000μL Pipetting accuracy: 2μL CV≤5%,
1000μL CV≤0.5%
8-channel pipetting module Fixed spacing, pressure sensing detection, with liquid level detection function Pipetting range: 1-200μL
PCR module Used for enzyme reaction and PCR reaction during the experiment,
Capacity 96×0.2ml
Temperature range: 4℃-99℃
Temperature control module Realize constant temperature control of reagents to meet low/high temperature incubation Temperature range: 4℃-99℃ Applicable to SBS standard microplate
Magnetic rack module Magnetic beads adsorption for different experimental needs during the experiment Match deep well plates, PCR plates and other microplates
Air filter module Built-in filtration system effectively prevents aerosol pollutants from leaking out The filtration efficiency of particles with a diameter of 0.3μm is no less than 99.9%
key Parameter
Product Parameters
Product Name AxiLona Automated Library Preparation System
Pipette module performance 8-channel Single module pipetting range 1-200μL, fixed spacing, pressure sensing detection
Single channel Single module pipetting range 1-1,000μL, capacitance/pressure dual sensing detection
Pipetting accuracy 2μL CV≤5%,1000μL CV≤0.5%
Robot arm configuration Single arm mounting 1+8 channel pipetting, intelligent gripper/open/close cover handle (optional)
Robot arm positioning accuracy ±0.1 mm
Bench plate positions 12 SBS standard plate positions
Anti-contamination system UV disinfection Radiation dose >100,000 μW·s/cm²
HEPA Laminar Flow Hood Positive pressure HEPA filtration
Overall size 720 × 650 × 730 mm(Length x Width x Height)
Total Weight ~45 Kg (without bench module/accessories)
Power Requirements Voltage 100-120V / 200-240V AC,50/60 Hz
Rated power Basic model <1400 VA
WorkiWorking environment Ambient temperature 15-35 ℃
Relative humidity 20%-80% RH, No condensation
Air pressure range 80-106 kPa
Copyright ©Axbio Inc. All rights reserved.